Dynamic
Instruments Inc. DI-803 Transducer Test Set
Stopped working
after an extended storage period. Suspect operating system
lost due to op. system rom battery failure. All functions were working before
storage. Comes up
with "ram passed" status, then no panel response.
|
pic |
sold |
|
Dynamic
Instruments Inc. DI-803 Transducer Test Set
Shaker motor badly damaged - needs replacement. Suspect operating system also
lost due to op. system rom internal battery failure. Case
top has small dents.
|
pic |
sold |
|
Fluke 12 multimeter
No display, kills batteries - suspect proprietary LSI chip
u/s.
|
pic |
. |
|
Fluke 8840A 5.5 digit multimeter w/ IEEE option
Cracked, non- functional display. Missing handle and one
rear foot. No further tests performed since we can't see
what's going on.
|
pic |
. |
|
HP 5302A counter plug-in
Channel A bad. Time base setting seems to be off by one
position.
|
pic |
. |
|
HP 5355A automatic frequency converter plug in for 5345A counter
No front panel response.
|
pic |
. |
|
Icom IC-02AT VHF handheld transceiver
Receiver ok, transmit quits after 3 seconds at either hi or lo
power. Traced to driver board - heating (not cooling) fixes
problem.
|
pic |
. |
|
Lambda LQ-532 0-40V 0-5A CV / CC regulated bench power supply
Max. voltage output, no V adjustment. Adjusting current pot
to zero takes output to 0V.
|
pic |
. |
|
Marconi 2018A RF synthesizer
OK except output decade attenuator assembly out of spec.
|
pic |
. |
|
Philips 3262 oscilloscope
Channel 1 bad. Poor triggering. No handle or CRT bezel.
|
pic |
. |
|
Philips 3264 4 channel oscilloscope
No trigger. Noisy trace cleans up after 20 minute warm
up. Ch3/4 gains twitchy.
|
pic
|
.
|
|
Revox A77 reel to reel tape recorder with portable case and
amplifiers
Poor high frequency response. Heads worn.
|
pic
|
.
|
|
Tektronix 335 oscilloscope
High voltage winding in T1002 open. Missing handle cap on
one side.
|
pic |
. |
|
Tektronix 465B oscilloscope
Poor trace focus, no sweep, missing handle covers and some knobs.
Ch2 variable gain shaft broken. Large printing stenciled on case.
|
pic |
sold |
Tektronix 475 oscilloscope
Noisy trace. Channel 1 rolls off at
100MHz Missing handle covers.
|
pic |
sold |
Tektronix 475 oscilloscope
Both channels roll off at 100MHz. Time base "A"
and "B" u/s.
Ch2 input bnc damaged. Missing handle covers, top of case
dented.
|
pic |
sold |
Tektronix 475 oscilloscope
Bad trace geometry and focus (bad CRT?). Time base "A" u/s.
Missing handle covers.
|
pic |
sold |
Tektronix 7A12 2 channel vertical amplifier
Channel 1 noisy, chop/alt bad, switch plastic damaged by wrong contact
cleaner. |
pic |
. |
Tektronix 7A18 2 channel vertical amplifier
Channel 2 gains do not track.
|
pic |
. |
Tektronix 7A18 2 channel vertical amplifier (no readout)
Channel 1 intermittent, channel B has at least 3 bad switch sections.
No tab.
|
pic |
. |
|
Tektronix 7A18 2 channel vertical amplifier
Channel 2 trigger u/s.
|
pic |
.. |
|
Tektronix 7A26 2 channel vertical amplifier
Channel 1 gain problem (0.5v to 1.0v). |
pic |
. |
|
Tektronix 7B92 time base
Poor trigger on "auto".
|
pic |
. |
|
Tektronix 7B92A time base
Poor trigger.
|
pic |
. |
|
Tektronix 7D20 digitizer
Was working when stored. Now has self test failure #642.
|
pic |
.
|
|
Tektronix 7904 oscilloscope mainframe
Power supply will not come up, backplane may be damaged, bad U825 / U2157.
Damaged knob.
|
pic |
.
|