PROLEX

DESIGN


Surplus and used
electronic test equipment

ANALYZERS

Analyzers
Computer Items
Counters
Fluke
HP (Agilent)
Manuals
Meters
Miscellaneous Items
Miscellaneous plug ins
Modules for 'scopes
Oscilloscopes
Power Supplies
Probes and Accessories
Signal Generators
Tektronix

Contact us

Purchase Details
Terms of sale

THE "BONE YARD"   (listed alphabetically by manufacturer)

pic

$EA


PAGE UNDER CONSTRUCTION - MORE DETAILS WILL BE ADDED SOON

All items in this category have some problems. They may be repairable, but for us they are not cost effective to repair due to a combination of projected repair time involved, availability of parts or lack of service information.  These items appear complete unless otherwise noted and will not be disassembled for specific parts.  Obvious item faults are described but other undetected faults may exist.  These items are sold "as is" and no further troubleshooting will be done.

For now, the "Bone yard" and "Tube" categories are exceptions to our "list all prices" policy.  Please contact us and we will try to accommodate your needs.
  

.

 .


Dynamic Instruments Inc. DI-803 Transducer Test Set
Stopped working after an extended storage period.  Suspect operating system lost due to op. system rom battery failure.  All functions were working before storage.  Comes up with "ram passed" status, then no panel response.

pic

sold


Dynamic Instruments Inc. DI-803 Transducer Test Set
Shaker motor badly damaged - needs replacement.  Suspect operating system also lost due to op. system rom internal battery failure.  Case top has small dents.

pic

sold


Fluke 12 multimeter
No display, kills batteries - suspect proprietary LSI chip u/s.

pic

.


Fluke 8840A 5.5 digit multimeter w/ IEEE option
Cracked, non- functional display.  Missing handle and one rear foot.  No further tests performed since we can't see what's going on.

pic

.


HP 5302A counter plug-in
Channel A bad.  Time base setting seems to be off by one position.

pic

.


HP 5355A automatic frequency converter plug in for 5345A counter

No front panel response.

pic

.


Icom IC-02AT VHF handheld transceiver

Receiver ok, transmit quits after 3 seconds at either hi or lo power.  Traced to driver board - heating (not cooling) fixes problem.



pic

.


IFR 1000-S service monitor with spectrum analyzer option
Spectrum analyzer, signal generator, receiver, modulator, power meter, modulation meter.  All functions ok except flakey power on switch, gen. output exactly 20 dbm below dial reading (bfo ok).  Batteries probably need replacement, but has provision for external dc supply as well as ac.  With front cover.

pic

sold


Lambda LQ-532  0-40V 0-5A CV / CC regulated bench power supply

Max. voltage output, no V adjustment.  Adjusting current pot to zero takes output to 0V.

pic

.


Marconi 2018A RF synthesizer

OK except output decade attenuator assembly out of spec.

pic

.


Philips 3262 oscilloscope
Channel 1 bad.  Poor triggering.  No handle or CRT bezel.

pic

.


Philips 3264 4 channel oscilloscope
No trigger.  Noisy trace cleans up after 20 minute warm up.  Ch3/4 gains twitchy.

pic

.


Revox A77 reel to reel tape recorder with portable case and amplifiers
Poor high frequency response.  Heads worn.

pic

.


Tektronix 335 oscilloscope
High voltage winding in T1002 open.  Missing handle cap on one side.

pic

.


Tektronix 465B oscilloscope

Poor trace focus, no sweep, missing handle covers and some knobs.  Ch2 variable gain shaft broken.  Large printing stenciled on case.

pic

sold


Tektronix 475 oscilloscope
Noisy trace.  Channel 1 rolls off at 100MHz  Missing handle covers.

pic

sold


Tektronix 475 oscilloscope
Both channels roll off at 100MHz.  Time base "A" and "B" u/s.  Ch2 input bnc damaged.  Missing handle covers, top of case dented. 

pic

sold


Tektronix 475 oscilloscope
Bad trace geometry and focus (bad CRT?).  Time base "A" u/s.  Missing handle covers.

pic

sold


 Tektronix 7A12 2 channel vertical amplifier

 Channel 1 noisy, chop/alt bad, switch plastic damaged by wrong contact cleaner.
pic

.


Tektronix 7A18 2 channel vertical amplifier
Channel 2 gains do not track.

pic

.


Tektronix 7A18 2 channel vertical amplifier
(no readout)
Channel 1 intermittent, channel B has at least 3 bad switch sections.  No tab.

pic

.


Tektronix 7A18 2 channel vertical amplifier

Channel 2 trigger u/s. 

pic

..


Tektronix 7A26 2 channel vertical amplifier

Channel 1 gain problem (0.5v to 1.0v).

pic

.


Tektronix 7B92 time base
Poor trigger on "auto".

pic

.


Tektronix 7B92A time base
Poor trigger.

pic

.


Tektronix 7D20 digitizer
Was working when stored.  Now has self test failure #642.

pic

.


Tektronix 7904 oscilloscope mainframe
Power supply will not come up, backplane may be damaged, bad U825 / U2157.  Damaged knob.

pic

.


Back to Home